<em>Radiologic Technology</em>
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Radiologic Technology, 80:401-409 2009
© 2009 American Society of Radiologic Technologists
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by KOWALCZYK, N.
Right arrow Articles by COMER, E.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by KOWALCZYK, N.
Right arrow Articles by COMER, E.

PEER REVIEW

Exposure Indicator Degradation From CR Plate Processing Delays

NINA KOWALCZYK, PhD, R.T.(R)(QM)(CT), FASRT and ELIZABETH COMER, BS, R.T.(R)

Purpose To determine the percentage of exposure indicator (EI) degradation that occurs during a delay between exposure and processing of the imaging receptor.

Methods Twenty-six images of a hand phantom, stepwedge and resolution test tool were created using a computed radiography (CR) system (Agfa Impax 6.3.1 SU5 CR, Agfa-Gevaert NV, Mortsel, Belgium). To control variables, exposures were made using the same technique, resulting in an EI of 2.0. The radiographic equipment, Agfa algorithms and processor and display monitor were held constant, and all imaging plates (IPs) were exposed and processed initially to rule out EI variation. Consecutive experimental exposures were made and each IP labeled by number and the time processed. To control ambient conditions, the exposed IPs were secured at room temperature in a radiation-free area until they were processed.

Results The EI degraded 8% within the first hour of delay in processing. After 24 hours, degradation was 16%, demonstrating that the EI initially drops quickly following exposure, but degrades at a slower pace as the processing delay increases.

Conclusion This study supports current literature by showing that more than half of the degradation that occurs in the first 24 hours happens within the first hour of delay in processing.