<em>Radiologic Technology</em>
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Radiologic Technology, 79:507-513 2008
© 2008 American Society of Radiologic Technologists
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by KURMIS, A. P
Right arrow Articles by FAZZALARI, N. L
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by KURMIS, A. P
Right arrow Articles by FAZZALARI, N. L

PEER REVIEW

Determining Disk Hydration Status With a MnCl2-based MR Model

ANDREW P KURMIS, PhD, JOHN P SLAVOTINEK, MBBS, CHRISTINE BARBER, BSc and NICOLA L FAZZALARI, PhD

Purpose An extensive body of literature demonstrates a strong correlation between intervertebral disk (IVD) hydration status (HS) and functional spinal integrity. However, to date, in vivo IVD HS assessment has relied largely on subjective and nonrepeatable measures. The aim of this study was to establish the consistency of signal homogeneity of a novel semisolid-state manganese chloride (MnCl2)-based phantom for HS correlation using conventional magnetic resonance (MR) imaging.

Materials and Methods Sixteen MnCl2 phantoms, of increasing relative molar concentration (range 0.01 to 2.9 mM), underwent axial MR imaging. Phantom signal-to-noise ratio measures were recorded for each concentration on several sequence types. Coefficient of variance data were calculated to determine the degree of MR signal variation at each concentration.

Results Analysis of variance testing suggested no significant difference in coefficient of variance data derived from phantom signal intensities using either T1- (P = .13) or T2-weighted sequence types (P = .96), suggesting a high degree of relative signal homogeneity.

Conclusions The findings of this study suggest that a MnCl2 phantom combined with a nonfield reactive, semirigid, gelatin suspension media can produce a predictable, concentration-related, homogeneous MR signal response. This may be an appropriate base material for a noninvasive model to allow accurate quantification of the hydration status of the in vivo human IVD.







HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2008 by the American Society of Radiologic Technologists.